Installation Guide For FM 200 Suppression System – Zulu Jam


Installing an FM 200 fire suppression system requires careful planning, precise execution, and adherence to safety standards. Below is a complete guide outlining the steps involved in the installation process:

Conduct a site survey:

Begin by conducting a thorough site survey to assess the layout, size, and specific fire risks of the area to be protected. Identify hazards, critical assets, and any special considerations that may impact the design and installation of the FM 200 fire suppression system.

Design the system:

Based on the site survey findings, work with a qualified engineer or fire protection specialist to design the FM 200 suppression system. Consider factors such as the type of hazard, required coverage area, system capacity, piping layout, and location of storage containers and discharge nozzles.

Obtain necessary permits:

Before proceeding with installation, obtain all required permits and approvals from local authorities having jurisdiction (AHJs). Ensure compliance with relevant building codes, fire regulations, and environmental regulations governing the installation of fire suppression systems.

Procure equipment and materials:

Once the design is finalized and permits are secured, procure the necessary equipment and materials for the FM 200 system installation. This includes FM 200 storage containers, discharge nozzles, piping, fittings, control panels, detection devices, and ancillary components.

Install storage containers:

Position the FM 200 storage containers in a designated storage area according to manufacturer’s guidelines and local regulations. Ensure proper anchoring and securement to prevent movement or damage during operation. Verify that access to the containers for maintenance and inspection is unobstructed.

Install piping network:

Install the piping network according to the approved design layout. Use appropriate piping materials and fittings compatible with FM 200 and capable of withstanding the required pressure levels. Ensure proper support, alignment, and clearance from obstructions to facilitate efficient agent distribution.

Install detection and control systems:

Mount fire detection devices, such as smoke detectors or heat sensors, in strategic locations throughout the protected area. Connect these devices to the control panel, ensuring proper wiring and communication protocols. Test the system to verify detection and alarm functionality. Also, install FM 200 discharge nozzles at predetermined locations within the protected space. Position the nozzles to provide uniform coverage and ensure adequate dispersion of the agent for effective fire suppression.